| An Use of Hard-coded Credentials vulnerability has been identified in Moxa’s network security appliances and routers. The system employs a hard-coded secret key to sign JSON Web Tokens (JWT) used for authentication. This insecure implementation allows an unauthenticated attacker to forge valid tokens, thereby bypassing authentication controls and impersonating any user. Exploitation of this vulnerability can result in complete system compromise, enabling unauthorized access, data theft, and full administrative control over the affected device. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| An exposed IOCTL with an insufficient access control vulnerability has been identified in the utility, MxGeneralIo, for Moxa’s industrial x86 computers. The affected utility, MxGeneralIo, exposes IOCTL methods that permit direct read and write access to MSR and system memory. A local attacker with high privileges could abuse these interfaces to perform unauthorized operations. Successful exploitation may result in privilege escalation on Windows 7 systems or cause a system crash (BSoD) on Windows 10 and 11 systems, leading to a denial-of-service condition. The vulnerability could slightly affect the confidentiality and integrity of the device, but availability might be heavily impacted. No impact to the subsequent system has been identified. |
| A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact" |
| A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description" |
| A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text" |
| An issue was discovered in Moxa EDR-810 Industrial Secure Router. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access configuration and log files (PRIVILEGE ESCALATION). |
| XML External Entity via ".AOP" files used by Moxa MX-AOPC Server 1.5 result in remote file disclosure. |
| Moxa MXView 2.8 allows remote attackers to cause a Denial of Service by sending overly long junk payload for the MXView client login credentials. |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. User-controlled input is not neutralized before being output to web page (CROSS-SITE SCRIPTING). |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition. |
| An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption. |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted. |
| An issue was discovered in Moxa DACenter Versions 1.4 and older. The application may suffer from an unquoted search path issue. |
| An exploitable information disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point. Retrieving a series of URLs without authentication can reveal sensitive configuration and system information to an attacker. |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method. |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface. |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused. |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur. |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded. |
| An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it. |