Search Results (416 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-73169 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-17 N/A
Nozomi Networks Labs identified a CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Modbus transaction management interface of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to store malicious script content that executes in the browser of any administrator who later opens an affected management page.
CVE-2026-73174 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-17 N/A
Nozomi Networks Labs identified a CWE-319: Cleartext Transmission of Sensitive Information vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a network-adjacent passive observer to intercept management traffic and recover sensitive device identity and network metadata in cleartext.
CVE-2026-79698 1 Advantech 14 Wise-6610, Wise-6610-cb, Wise-6610-eb and 11 more 2026-09-11 9.9 Critical
A vulnerability was identified in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. This vulnerability affects the function nodered_lib_apply of the component Node-RED Library. Such manipulation of the argument act leads to command injection. The attack can be launched remotely. The exploit is publicly available and might be used. Upgrading to version 1.2.4_20260821 is able to resolve this issue. It is advisable to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
CVE-2026-43833 1 Advantech 1 Adam-3600 2026-09-11 5.3 Medium
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-43832 1 Advantech 1 Adam-3600 2026-09-11 7.5 High
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-43831 1 Advantech 1 Adam-3600 2026-09-11 7.5 High
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-43830 1 Advantech 1 Adam-3600 2026-09-11 9.8 Critical
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-43829 1 Advantech 1 Adam-3600 2026-09-11 7.5 High
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-79697 1 Advantech 14 Wise-6610, Wise-6610-cb, Wise-6610-eb and 11 more 2026-09-08 9.9 Critical
A vulnerability was determined in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. This affects the function basicstation_apply of the component Basic Station Certificate-Deletion Handler. This manipulation of the argument act causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 1.2.4_20260821 is able to mitigate this issue. Upgrading the affected component is advised. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
CVE-2026-2670 1 Advantech 14 Wise-6610, Wise-6610-cb, Wise-6610-eb and 11 more 2026-09-07 7.2 High
A vulnerability was identified in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. Affected is an unknown function of the file /cgi-bin/luci/admin/openvpn_apply of the component Background Management. Such manipulation of the argument delete_file leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used. Upgrading to version 1.2.4_20260821 is able to address this issue. It is advisable to upgrade the affected component. The vendor explains: "The delete operation has been redesigned to map the requested file type to a fixed allowlisted path, require a numeric tunnel ID, reject invalid requests, and use the native filesystem API (fs.unlink) instead of constructing a shell command from request data."
CVE-2026-14162 1 Advantech 1 Hospital Quering Management 2026-07-01 9.8 Critical
Hospital Queuing Management developed by Advantech has a Sensitive Data Exposure vulnerability, allowing unauthenticated remote attackers to access a specific URL to obtain API documentation.
CVE-2024-50370 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 9.8 Critical
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
CVE-2024-50369 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50368 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 7.2 High
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50358 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 7.2 High
A CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.
CVE-2022-3386 1 Advantech 1 R-seenet 2026-06-17 9.8 Critical
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can use an outsized filename to overflow the stack buffer and enable remote code execution.
CVE-2022-3385 1 Advantech 1 R-seenet 2026-06-17 9.8 Critical
Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can remotely overflow the stack buffer and enable remote code execution.
CVE-2026-36226 1 Advantech 1 Webaccess/scada 2026-05-22 6.1 Medium
Cross Site Scripting vulnerability in Advantech WebAccess/SCADA 8.0-2015.08.16 allows a remote attacker to obtain sensitive information via the decryption field in the Create New Project User component
CVE-2026-6888 1 Advantech 8 Ecowatch Saas-composer, Iot Edge Linux Docker, Iot Edge Windows and 5 more 2026-05-13 7.2 High
Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to execute arbitrary commands via a specific interface, potentially enabling the attacker to access, modify, or delete sensitive information within the database.
CVE-2008-5848 1 Advantech 14 Adam-6015, Adam-6017, Adam-6018 and 11 more 2026-04-23 N/A
The Advantech ADAM-6000 module has 00000000 as its default password, which makes it easier for remote attackers to obtain access through an HTTP session, and (1) monitor or (2) control the module's Modbus/TCP I/O activity.